Our company has developed devices to meet various applications as devices to secure safety when the door is opened/closed.
DPX-81 Series / Infrared Type Photoelectric Relay
Features
Multi function, standardization
Easy adjusting of optical axis
No interference between optical axes
Long, life, easy maintenance
Specifications
Light source
Infrared modulated klght
Rated voltage
DC24V (working voltage 16~30V)
Rated output current
2A continyous (contactless output)
Effective distance
Max.2m(distance between light transmitter and receiver not posing any problem in practical use even when the light transmitting/receiving glass surface is contaminated)
DPX-83-0
DPX-81 Series / Infrared Type Photoelectric Relay
Number of beams
Shape, quiof hgh transmitter and receeive
Type of set product
Part type
Controller
Light transmitter
Light rece ver
1beam
Cylindrical type 1 beam
DPX-81 -1
DPX-81
TI-8L
TI-8R
Outer plate installation type 1 beam
DPX-81-0
TO-8L
TO-8R
2beams
Cylindrical type 2 beam
DPX-82-1
DPX-82
TI-8L
TI-8R
Cylindrical type 1 beam Outer plate installation type 1 beam
DPX-82-0
TI-8L TO-8L
TI-8R TO-8R
3beams
Cylindrical type 3 beam
DPX-83-1
DPX-83
TI-8L
TI-8R
Cylindrical typel 2 beam Outer plate installation type 1 beam
DPX-83-0
TI-8L TO-8L
TI-8R TO-8R
Note:
Cylindrical type is mainly used for inside use.
Outer plate installation type is used for outside use.
Reflection Type Photoelectric Switch
Features
Installable in places where conventional transmission type cannot be installed
Optical axis adjustment is not required
The incident angle of light reflected from the object to be detected is measured electrically, thereby detecting the presence of any object.
Specifications
Type
TDS300
Light source
Infrared rays
Rated voltage
DC24V (working voltage 16~30V)
Rated output current
100mA
Effective distance
Max. 2m (adjustable)
TDS300
Photoelectric Switch for Handrail
Specifications
Type
TE 3HC
Light source
Infrared modulated light
Rated voltage
DC24V (working voltage 18~30V)
Rated load current
80mA
Effective distance
Max. 1m
TE 3HC
Photoelectric Switch for Handrail
<
Touch Sensor
Specifications
Type
DFS-5
DA-688,758,788
Rated voltage
DC24V (working voltage 16~30V)
Contact
DC30V / 1A
Working temperature
-20°C~+70°C
Application
For preventing being pinched by the door (for door opening signal)
For High-low step
DFS-5
Door Front Switch (Electrical type)
Features
Simple structure and easy maintenance without nececcity of adjustment
High detecting sensitivity
Wide detection range
Specifications
For Sliding Door
Product name
Door end switch
Timer
Curlcord
Type
DFS-2
RY-15
Rated voltage
DC24V (Working voltage 16~30V)
Contact capacity
DC30V / 1A
DC30V / 3A (Resistance load)
Max.current 0.5A
Working temperature
-20°C~+70°C
Other
Release time limit 2~6seconds (setvalue: 3~4seconds)
Elongation 1000mm
For Folding Door, For glide Slide Door
Product name
Door end switch
Timer
Type
DFS-4
RY-15
Rated voltage
DC24V (working voltage 16~30V)
Contact capacity
DC30V / 1A
DC30V / 3A (Resistance load)
Working temperature
-20°C~+70°C
Other
Release time limit 2~6 seconds (set value : 3~4 seconds)
DFS-2Type
DFS-4Type
Door Front Switch (Electrical type)
Door front switch (air type)
Features
Soft-touch, high-sensitivity (min. 2 mbar)
Adjustable operating sensitivity
Detectable in all directions
Equipped with an orifice mechanism for prevention of malfunctions caused by fluctuations in temperature
Specifications
Type
DW 40 (without case) / GK11 (with case)
Maximum contact capacity :
DC24V/50mA : resistance load
Detectable pressure range :
2 mbar ~ 150 mbar
Specificified temperature range :
-15°C ~+70°C
GK-11
Mat Switch
Features
Simple structure, adjustment not required
High detecting sensitivity
Specifications
Rated voltage
DC24V (working voltage 16~30V)
Maximum current
0.5A (resistance load)
Contact resistance
Max.10mΩ
Working temperature
-20°C ~+70°C
Length (mm)
Width (mm)
Thickness (mm)
600
200
11
1400
200
11
Mat switch
Mat Switch
CT-8 Series Time Limit Relay
Features
Warning buzzer sounds before door is closed
The door is not closed while any person is on the steps
Closong door can be reversed in an emergency by operating the driver's switch
Double safety device is incorporated to prevent the door fyom opening during running